Index  >> Electric & Electronic Materials  >> Dosing Pump Series  >> CS074-3  
 
 
        .CS074-3S
        .CS074-3L.3LST
     Dosing Pump Series - Design for Dosing Pump
 
    CS074-3 Series      Dosing Pump    
 
   
CS074-3S   CS074-3L.3LST
 
 Feature  
 
  • Working life > 2000 hours.
  • Thermoplastic rubber tube, excellent resistance to abrasion and resist ozone, UV, acid, alkali, most oils and lubricants.
 
 Technical Specifications  
 
Model  CS074-3S
Working voltage  DC12V & DC24V
Load current  0.12A
Starting current  0.40A
Dosage
﹝measure by water﹞
 3∼50ml/min±10%
Entrance head  ≦2m
Exit head  ≦20m
Tube size
﹝mm﹞
 ID:2.6
 OD:4.9
Dimensions
Measurement
 L35.5 x W55.2 x H84.5mm
Weight
﹝g﹞
 72
 
 Feature  
 
  • Working life > 2000 hours.
  • Thermoplastic rubber tube, excellent resistance to abrasion and resist ozone, UV, acid, alkali, most oils and lubricants.
  • A special peristaltic tube is designed to resist acid and alkali (such as hydrofluoric acid 55%).
 
 Technical Specifications  
 
Model  CS074-3L
 CS074-3LST
Working voltage  DC12V & DC24V
Load current  0.58A
Starting current  0.96A
Dosage
﹝measure by water﹞
 140∼330ml/min±10%
Entrance head  ≦2m
Exit head  ≦20m
Tube size
﹝mm ﹞
 ID:4.8
 OD:8.0
Dimensions
Measurement
 L58.5 x W88.4 x H70.4mm
Weight
﹝g﹞
 220
 
 Not to use liquid  
 
Benzene
Cyclohexane
Kerosene
Nitric acid- 70%
Carbon tetrachloride
Ethyl chloride
Trichloroethylene
Perchloroethylene
 
Chlorobenzene
Freon
Lacquer
Toluene
Chloroform
Gasoline, unleaded
Naphtha
 
 Mechanical Dimensions  
 
 
 
 Mechanical Dimensions  
 
 
 
 A Method Of Rubber Hose
 Replacement
 
 
 
1.Clamp pump's upper
   hook outward with a
   Needle-nosed pliers.
2.Follow step 1 to clamp
   pump's lower hook
   outward and lift the
   cover up.
 
 
3.Loosen the cover
   assembly.
4.Remove the hose as
   well as the assembly of
   drive wheel with rollers
 
5.Fit the new hose in
   reverse order
 
 A Method Of Motor
 Replacement
 
 
 
1.Clamp pump's upper
   hook outward with a
   Needle-nosed pliers.
2.Follow step 1 to clamp
   pump's lower hook
   outward and lift the
   cover up.
 
 
3.Loosen the cover
   assembly.
4.Remove the 2 screws
   which be used to fasten
   motor in the upper and
   lower sides.
 
5.Loosen the lower cap
   and fit the new motor in
   reverse order.
   
 
 馬 達 電 壓 之 調 變  
 
  可調變輸出電壓的大小﹝如下電路圖﹞來調整液體出量的快流與慢流。
 
 
PS:Vout之輸出大小是基於Vin之輸入大小,如Vin之輸入16V則Vout可輸出到14V。
 
 Flow Rate Show  
 
 
 
Voltage adjust small ,flow rate becomes slow;
voltage adjust large ,flow rate becomes faster.
 

 
  CS074-3 Series DM Download